D-24 Psion Teklogix NEO Hand-Held Computer User Manual
Appendix D: Teklogix Imagers Applet
EAN 8
D.5.6 EAN 8
Enabled
Set this parameter to on to enable “EAN 8”.
Check Digit Strip
If you enable this parameter, a check digit is stripped from the decoded bar code data.
Supplements 2 and Supplements 5
Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in
length. Usually, data from an addendum is a suffix to the main symbol output data.
Mandatory Enabled
When this parameter is set to on, the imager does not accept the main bar code without a
supplement.
Supplements Separator
Supplements Separator is a space that is added between the EAN 8 bar code and the Supple-
ment code/Addenda.
D.5.7 UPC-A
Enabled
Set this parameter to on to enable “UPC-A”.
Check Digit Strip
If you enable this parameter, a check digit, if present, is stripped from the decoded bar code
data.
Number System
If this parameter is enabled, the number system digit is transmitted with the decoded bar
code data.
Supplements 2 and Supplements 5
Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in
length. Usually, data from an addendum is a suffix to the main symbol output data.