Chapter 24: 802.IQ Settings
802.IQ v1/v2 Common Features
304 Psion Teklogix 9160 G2 Wireless Gateway User Manual
was rebooted and, if so, how to recover. If the controller was rebooted, the mobile computer
closes all sessions and fully re-initializes. If the base station was rebooted, or if the mobile
computer moved to a different 9160 G2, a warm initialize is done (no data will be lost).
The Beacon Period parameter acceptable value ranges from 1 to 20 seconds. The default
value is 2.
Terminal Offline Timeout
This parameter sets the time (in minutes) before the 802.IQ task on the 9160 G2 will send an
offline message to the cellular master declaring the mobile computer offline.
The acceptable value ranges from 1 to 240. The default value is 5.