Chapter 6: Peripheral Devices & Accessories
Powered Cradle Installation In High Voltage Vehicles
Psion Teklogix 7535 G2 Hand-Held Computer User Manual 195
longer lock the 7535 G2 securely in the cradle. For replacement parts and instructions
contact Psion Teklogix. Partial disassembly is required.
6.11.5 Powered Cradle Installation In High Voltage Vehicles
Installation of powered cradles in vehicles that operate above 60VDC require special
consideration.
Due to the hazardous voltages present on these vehicles, it is necessary to ensure that the
powered cradle power supply cable connector is not accessible to the vehicle operator, and
does not get exposed to water or other liquids. This can be accomplished in one of the fol-
lowing ways:
Ensure the power connector is installed in a dry location on the vehicle, away from the
vehicle operator’s reach (perhaps under a vehicle dash or in a sealed housing).
Cover the power connector with a waterproof heat shrink material (see “Extreme Wet
Environments” below for additional details).
Wrap the connector securely with a waterproof electrical tape in an area out of the
vehicle operators reach.
All other installation requirements outlined in this document should also be followed for
High Voltage vehicles to insure safe installation and operation of the powered cradle.
6.11.5.1 Extreme Wet Environments
For extreme wet environments, or environments where it is difficult to restrict vehicle oper-
ator access to the power connector, Psion Teklogix offers a waterproof heat shrink kit (P/N
1030022). The kit contains 3 pieces of waterproof, high shrink ratio heat shrink tubing
which can be used to encapsulate the entire connector assembly. If using this kit, please
ensure that you order sufficient material to cover installation and service, remembering that
heat shrink is one-time use, and must be replaced if it is removed from the connector for any
reason.
Warning: Voltages exceeding 60VDC are considered hazardous. For powered cradle
installations on vehicles with batteries above this voltage, ensure the powered
cradle power connector is mounted in a dry location on the vehicle, or that
the connector is insulated with an appropriate waterproof material after
installation. The connector must also be installed out of the vehicle opera-
tors reach. Exposing an accessible power connector to water or other liquids
could create a hazardous situation resulting in serious injury or death.